HEAVY WELDED CONNECTORS

Heavy Duty Face Mount Joist Hangers
Product
Code
W
in
H
in
No. of Joist Joist Size
NVFH 24 1 916 1 2X4
2X6
NVFH 26 1 916 1 2X6
2X8
NVFH 28 1 916 1 2X8
2X10
NVFH 210 1 916 1 2X10
2X12
NVFH 212 1 916 11½ 1 2X12
2X14
2X16
NVFH 24-2 3 18 2 2X4
2X6
NVFH 26-2 3 18 2 2X6
2X8
NVFH 28-2 3 18 2 2X8
2X10
NVFH 210-2 3 18 2 2X10
2X12
NVFH 212-2 3 18 11½ 2 2X12
2X14
2X16
NVFH 36 2 916 1 3x6
3x8
NVFH 38 2 916 1 3x8
3x10
NVFH 310 2 916 1 3x10
3x12
NVFH 312 2 916 11½ 1 3x12
3x14
3x16
NVFH 36-2 5 18 2 3x6
3x8
NVFH 38-2 5 18 2 3x8
3x10
NVFH 310-2 5 18 2 3x10
3x12
NVFH 312-2 5 18 11½ 2 3x12
3x14
3x16
NVFH 26-3 4 58 3 2x6
2x8
NVFH 28-3 4 58 3 2x8
2x10
NVFH 210-3 4 58 3 2x10
2x12
NVFH 212-3 4 58 11½ 3 2x12
2x14
2x16
NVFH 28-4 6 18 4 2x8
2x10
NVFH 210-4 6 18 4 2x10
2x12
NVFH 212-3 6 18 11½ 4 2x12
2x14
2x16
NVFH 44 3 916 1 4x4
4x6
NVFH 46 3 916 1 4x6
4x8
NVFH 48 3 916 1 4x8
4x10
NVFH 410 3 916 1 4x10
4x12
NVFH 412 3 916 11½ 1 4x12
4x14
4x16
NVFH 66 1 6x6
6x8
NVFH 68 1 6x8
6x10
NVFH 610 1 6x10
6x12
NVFH 612 11½ 1 6x12
6x14
6x16
NVFH 86 1 8x6
8x8
NVFH 88 1 8x8
8x10
NVFH 810 1 8x10
8x12
NVFH 812 11½ 1 8x12
8x14
8x16

Joist size Fv=175 psi Shear Capacity (Lbs.)(2)(6)
Uplift 160% Gravity 100%
2x4 980 615
2x6 1540 960
2x8 2030 1270
2x10 2590 1620
2x12 3150 1970
2-2x4 1960* 1230
2-2x6 3080 1925
2-2x8 4060 2540
2-2x10 5180 3240
2-2x12 6300 3940
3x6 2570 1600
3x8 3380 2115
3x10 4320 2700
3x12 5250 3280
2-3x6 5130* 3210*
2-3x8 6760* 4230*
2-3x10 8640* 5400*
2-3x12 10,500* 6560*
3-2x6 4620* 2890*
3-2x8 6090* 3805*
3-2x10 7770* 4860*
3-2x12 9450* 5905*
4-2x8 8120* 5080*
4-2x10 10,360* 6480*
4-2x12 12,600* 7880*
4x4 2290* 1430*
4x6 3590* 2250*
4x8 4740* 2950*
4x10 6040* 3780*
4x12 7350* 4590*
6x6 5650* 3530*
6x8 7700* 4815*
6x10 9750* 6100*
6x12 11800* 7380*
8x6 7700* 4810*
8x8 10500* 8560*
8x10 13300* 8310*
8x12 16100* 10060*
H
(in)
2-2x
Headers
No. of 16d Nails
10d x 1½" (1)
No. of Joist Nails
Allowable loads (Lbs.)(2)
Uplift 160% Gravity 100%
12 9 1550 980
18 15 3130 1900
24 21 2800 2950
30 27 6600 4050
11½ 36 33 8400 5150


  1. For one or two joists side by side, use10dx1 nails from each side. For 3 Joists side by side, user 16dx3¼ sinker nails from each side and 10dx1½" nails from opposite side. For 4 Joists, used 16d sinker nails from each side.
  2. Use hanger capacity or shear capacity whichever is less. Joist Shear capacity shown * exceeds hanger capacity. For these joists use hanger capacity.
  3. All design conforms to Latest Editions of FBC, IBC and IRC.
  4. Structural steel shall conform to ASTM A36, yield strength 36000 psi.
  5. All welding shall be minimum 316 " with E70 electrodes and shall conform to latest AISC/AWS codes. All welds shall be fillet welds.
  6. All nail values in wood comform to latest Edition of NDS for southern Pine, G=0.55. Values of other species shall be adjusted as per NDS. This applies also to shear values of joists.
  7. Steel stress is not increased by 33%.
  8. Provide plywood shims to close the gap between joist and steell hangers to prevent bending if necessary.
  9. All products are painted Royal Blue or Galvanized.

More Wood to Wood Connectors
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8


Nu-Vue Industries, Inc. 1055 East 29th Street Hialeah, FL. 33013
Telephone: (305) 694-0397 Fax: (305) 694-0398 info@nu-vueindustries.com | Shipping | Warranty