HEAVY WELDED CONNECTORS

Wood to Wood Truss Hangers NVFHE

Carrier Truss Verticals ALLOWABLE LOADS (lbs.)
Carried Truss 12" HIGH  16" HIGH
1 Ply NVFHE1C 2 Ply NVFHE2C 3 Ply NVFHE3C 4 & 5 Ply
NVFHE4C, 5C
1 Ply NVFHE1D 2 Ply NVFHE2D 3 Ply NVFHE3D 4 & 5 Ply
NVFHE4D, 5D
1 PLY
1-2x6
Gravity 3520 3520 3520 3520 6510 6510 6510 6510
Uplift 3520 3520 3520 3520 6510 6510 6510 6510
2 PLY 
2- 2x6
Gravity 4960 4960 4960 4960 10150 10150 10150 10150
Uplift 4960 4960 4960 4960 7890 10150 10150 10150
3 PLY 
3- 2x6
Gravity 8205 11000 11000 11000 10835 15820 15925 15925
Uplift 5260 9310 9870 9870 7890 13965 14805 14805
4  & 5 PLY
4- 2x8
5-2x8
Gravity 8205 11000 11000 11000 10835 15820 15925 15925
Uplift 5260 9310 9870 9870 7890 13965 14805 14805


NVFHE1C, NVFHE2C, NVFHE3C & NVFHE4C & NVFHE5C-12” high
NVFHE1D, NVFHE2D, NVFHE3D & NVFHE4D & NVFHE5D-16” high



Weld A: 8” long for 12” high & 10” long for 16” high plates and 1/2” at top.
Weld B: Continuous 3/16" Fillet.
Weld C: Continuous 3/16" Fillet.

Plates a: 4" x 3/16" x 12" or 16"
Plate b: (X+1/2") x 3/16” x 12” or 16”
Plate c: (X+1/2”) x 3/16” x 4 3/16”
NVFHE
Carried Truss Verticals
1C, 1D
2 x 4
2C, 2D
2 x 6
3C, 3D
2 x 8
4C, 4D
2 x 8
5C, 5D
2 x 8

Revised 11/21/2005
Revised 08-01/2005
Revised 10/15/2008

Structural Notes: Wood to concrete and Wood to Wood connectors

1. All designs conforms to 2006/2007 FBC and 2006 IBC and IRC and NDS 2005.
2. 3/16" thick structural steel shall conform to ASTM A36 yield strength 36000psi. All Bolt holes are 13/16" diameter.
3. All welding shall be minimum 3/16" with E70 electrodes and shall conform to latest AISC/AWS codes. All welds shall be fillet welds.
4. All power fasteners wedge bolt anchors shall be manufacturer's published information. Minimum anchor diameter is 3/4" and anchor embedment shall be 6".
5. Uplift values in concrete shown are reduced for bolt spacing and edge distance. Power Fasteners are used without 33% increase in allowable values.
6. All bolt values in wood conform to NDS 2005 for southern pine, G=0.55. Values for other species shall be adjusted as per NDS 2005.
7. Bolts shall not penetrate Truss top and bottom cords and shall only be through Truss Verticals. Bolts thru wood shall conform to section 11.1,2 of NDS 2001 and table 11 G for shear values.
8. This connector shall only be used for wood members loaded parallel to grain.
9. Steel stress is not increased by 33%.
10. Provide plywood shims to close the gap between carried truss and steel connectors to prevent bending of bolts.
11. All products are painted Royal Blue for easy Identification.