Design Features: To anchor existing roof truss to resist high Uplift loads

Materials:
(1) 1/4” Black steel – ASTM A36 Steel
(2) Minimum concrete strength of 3,000 psi

Tie Beam b

Product Code  Thickness
Dimensions
Fasteners
Uplift Loads
W H BS
Wood Truss
Tie Beam A
Tie Beam B
Design A Design B
1/4″
3 1/2″
4″ 4″
4-10d X 1/2”
nails

1 1/4”𝜙 Tapcons
1 3/4” Embedment

1-1/4” 𝜙 Tapcon
1 3/4” Embedment
860 575*

structuralangle44m