Wood to Concrete Truss Hanger NVFHE

Concrete Strength
PSI
Allowable Lateral Loads (lbs.) Power Fasteners
Carrier Truss
12″ High
16″ High
1 Ply
NVFHE1A
2 Ply
NVFHE2A
3 Ply
NVFHE3A

4 Ply
NVFHE4A

5 Ply
NVFHE5A
1 Ply
NVFHE1B
2 Ply
NVFHE2B
3 Ply
NVFHE3B
4 Ply
NVFHE4B
5 Ply
NVFHE5B
2000
Gravity
4550 4550 7300 7300 7300 1750 1750 1750 3450 3450
Uplift
4550 4550 7400 8900 7400 1330 2680 3580 4030 4030
2500
Gravity
4725 4725 7300 7300 7300 1765 1765 1765 3505 3505
Uplift
4725 4725 7700 9250 7700 1330 2680 3580 4030 4030
3000
Gravity
4900 4900 7300 7300 7300 1780 1780 1780 3560 3560
Uplift
4900 4900 2390 8000 9600 9800 7550 7550 12000 13200
Carried Truss
a (in)
b (in)
3A
1 1/4″
3
4A, 4B
1 1/8″
4 3/4″
5A, 5B
1 1/4″
6
PLY
X(IN)
1
1 3/4″
2
3 1/2″
3
5 1/2″
4
7
5
8 1/2″

nvfhe

Structural Notes: Wood to concrete and wood to wood connectors.

1) All design conforms to 2006/2007 FBC and 2006 IBC and IRC AND NDS 2005.
2) 3/16″ thick structural steel shall conform to ASTM A36, yield strength 36000 psi. All bolt holes are 13/16″ diameter.
3) All welding shall be minimum 3/16″ with E70 electrodes and shall conform to latest AISC/AWS codes. All welds shall be fillet welds.
4) All Power Fasteners wedge bolt anchors shall manufacturer’s published information. Minimum anchor diameter is 3/4″ and anchor embedment shall be 6″.
5) Lateral values in concrete shown are reduced for bolt spacing and edge distance. Power fasteners are used without 33% increase in allowable values.
6) All bolt values in wood conform to NDS 2001 for southern pine, G=0.55. Values for other species shall be adjusted as per NDS 2005. Bolts are 3/4″ diameter.
7) Bolts shall not penetrate Truss top and bottom chords and shall only be through Truss Verticals. Bolts thru wood shall conform to section 11.1.2 of NDS 2005 and table 11 G for shear values.
8) This connector shall only be used for wood members loaded parallel to grain.
9) Steel stress is not increased by 33%.
10) Provide plywood shims to close the gap between truss chords and steel connectors to prevent bending of bolts.
11) Lateral loads shall be combined with Uplift loads to satisfy the equation:

lateralloads12) All products are painted Royal Blue for easy identification.

vipen

Concrete Strength
PSI
Allowable Lateral Loads (lbs.) Power Fasteners
Carrier Truss
12″ High
16″ High

1 Ply

NVFHE1A

2 Ply
NVFHE2A
3 Ply
NVFHE3A
4 Ply
NVFHE4A
5 Ply
NVFHE5A
1 Ply
NVFHE1B
2 Ply
NVFHE2B
3 Ply
NVFHE3B
4 Ply
NVFHE4B
5 Ply
NVFHE5B
2000
L1
1600 1600 3200 3200 3200 1750 1750 1750 3450 3450
L2
890 1790 2390 2690 2690 1330 2680 3580 4030 4030
2500
L1
1625 1625 3250 3250 3250 1765 1765 1765 3505 3505
L2
890 1790 2390 2690 2690 1330 2680 3580 4030 4030
3000
L1
1650 1650 3300 3300 3300 1780 1780 1780 3560 3560
L2
890 1790 2390 2690 2690 1330 2680 3580 4030 4030
Carried Truss
a (in)
b (in)
3A
1 1/4″
3
4A, 4B
1 1/8″
4 3/4″
5A, 5B
1 1/4″
6
PLY
X(IN)
1
1 3/4″
2
3 1/2″
3
5 1/2″
4
7
5
8 1/2″

nvfhe

Structural Notes: Wood to concrete and wood to wood connectors.

1) All design conforms to 2006/2007 FBC and 2006 IBC and IRC AND NDS 2005.
2) 3/16″ thick structural steel shall conform to ASTM A36, yield strength 36000 psi. All bolt holes are 13/16″ diameter.
3) All welding shall be minimum 3/16″ with E70 electrodes and shall conform to latest AISC/AWS codes. All welds shall be fillet welds.
4) All Power Fasteners wedge bolt anchors shall manufacturer’s published information. Minimum anchor diameter is 3/4″ and anchor embedment shall be 6″.
5) Lateral values in concrete shown are reduced for bolt spacing and edge distance. Power fasteners are used without 33% increase in allowable values.
6) All bolt values in wood conform to NDS 2001 for southern pine, G=0.55. Values for other species shall be adjusted as per NDS 2005. Bolts are 3/4″ diameter.
7) Bolts shall not penetrate Truss top and bottom chords and shall only be through Truss Verticals. Bolts thru wood shall conform to section 11.1.2 of NDS 2005 and table 11 G for shear values.
8) This connector shall only be used for wood members loaded parallel to grain.
9) Steel stress is not increased by 33%.
10) Provide plywood shims to close the gap between truss chords and steel connectors to prevent bending of bolts.
11) Lateral loads shall be combined with Uplift loads to satisfy the equation:

lateralloads12) All products are painted Royal Blue for easy identification.

vipen